Provisioning Zebra TC5x devices
ITF14, The barcodes on outer cartons do not scan.
Above is an example of an ITF14 barcode. If this style of barcodes are not scanning, you will need to enable Interleaved 2 of 5 symbols as follows:
From the application drawer open the DataWedge application.
- Click on the
Profile0 (default) - Scroll down to
Barcode inputand selectConfigure scanner settings - Select
Decoders - Scroll down to
Interleaved 2 of 5 - Set the
Enabledcheck box - Set the
Check DigittoUSS Check Digit - Tick the box
Report Check Digit
You can test the scanner with the following two barcodes.
The following barcode is a well formatted barcode and should scan.
The following barcode has a bad check digit and should not scan.
The barcode only scans when the keyboard is on screen.
First try:
From the application drawer open the DataWedge application.
- Open the
3-Dotmenu and selectSettings - Scroll to the bottom and select
Restore.
This will reset the Data Wedge application to its factory settings. If you have previously enable Interleaved 2of5 barcode you will need to enter these settings again.
If the above does not work you can try the following.
From the application drawer open the DataWedge application.
- Click on the
Profile0 (default) - Scroll down to
Key stroke outputand selectKey event options - Under
Charactersselect the optionSend Characters as Events
